Biomedical imaging is an area where QuantIC seeks to expand its contributions

Quantum imaging for healthcare

Discover how researchers at the University of Glasgow are imaging through the body.

Quantic technologies for healthcare

IMAGING THROUGH THE BODY

Traditional methods for imaging inside the body or the human brain require expensive and/or invasive techniques (e.g. fMRI, PET). Functional near infra-red spectroscopy is an optical technique that promises to solve these limitations.  

At QuantIC researchers are combining single-photon detection with precise time resolution and machine learning techniques to image through highly diffusive media such as tissue.

Results so far show that images can be recovered through many 10’s mm of highly-scattering, tissue-like material obtaining mm resolution of buried objects. Our goal is to achieve MRI-like image quality using tissue simulations showing that it might be possible to non-invasively image the outer 10s mm of the brain.

Video

SINGLE-FIBRE ENDOSCOPE

Traditional endoscopes are based on bundles of many thousands of optical fibres, one fibre for every pixel in the image. 

A less intrusive endoscope could be based on a single-fibre the width of a human hair. However, when an image is transmitted along a single-fibre, cross-talk between modes, scrambles the light to make the image unrecognisable.

At QuantIC we are making single fibre endoscopes possible. Using advanced computing, beam shaping, and photon timing allows a 3D image to be extracted from this noise.  Such systems would be much less intrusive to imaging inside the human body.

Video

IMAGING WITH HIGHER ORDER CORRELATIONS

Usually when trying to characterise transmission through complex media, e.g. turbid water, one analyses the transmitted light. However, in many cases the complex media can only be accessed from one side.

We are examining how media can be characterised from the back-scattered light alone, meaning that the transmitted light can be controlled (e.g. focussed onto a buried object) using only the backscatter information.

Such approaches would transform many imaging systems ranging from the single-fibre endoscope under development in QuantIC to the reconstruction of hidden complex objects in biological tissue.

Video

 

 

QUANTUM ILLUMINATION MICROSCOPE/IMAGER

In conventional imaging, the sensor signal comprises the real image to which is added sensor noise and indeed any background light which is inadvertently or deliberately introduced. This background light and sensor noise can degrade or obscure the real image.

As a new demonstrator in QuantIC phase two, we are replacing the classical illumination, where photons arrive one by one, with quantum illumination, where the photons arrive two by two.

These photon pairs act as probe and reference where every probe photon in the image is authenticated using its correlated (entangled) reference. Results so far have shown that even when the background light has the same wavelength, polarisation, and statistics of the pair source it can be ≈99% eliminated from the image using the photon pair information to distinguish real photon events from the noise.

This type of image may have applications in ultra-low light conditions or when the outputs from different imaging system need to be distinguished/encoded from each other. This technology will greatly enhance the functionality of medical microscopes.

Video

 

SUB SHOT NOISE IMAGER

Even the most stable classical light source is subject to intensity fluctuations that arise fundamentally from its particle-like (photon) nature. These fluctuations are called shot noise which in any one image pixel corresponds to the square root of the number of photons detected. For ultra-low light images where the number of photons per pixel can be typically a single digit in resulting noise is comparable to the signal itself.

In QuantIC phase one we developed a family of light sources where the photons were created in pairs, correlated in time and wavelength, where one of the photons can be the probe and the other the reference. Through QuantIC, these photon-pair sources are now commercially available and the thrust of the second phase is to use them within imaging applications.

Using this photon-pair, probe-reference, approach it is possible to scan an illumination beam over a sample and use the measured reference to negate the photon-by-photon shot noise. In work to date we have shown several dB of improvement beyond the classical limit and the suppression of sensor noise.

Video

NANOPHOTONIC SOURCE

Key to many quantum systems are sources of light that produce entangled pairs of photons. Usually, these photons are created using non-linear crystals which convert photons from a laser into photon pairs of longer wavelengths. But the range of wavelengths possible are restricted by the properties of crystals that can be grown.

As a new demonstrator in QuantIC phase two, we are using arrays of nanostructures that can be designed to create a broader range of wavelengths to produce entangled photons at precise wavelengths in the infra-red, or longer, for specific sensing requirements. Beyond being a pivot component in quantum optics, even as a classical source this approach might yield sources of light of unparalleled brightness for bio-sensing applications.

Hyperspectral bioimaging could provide in-depth analysis of tissue such as cancerous tumours.

Video

 

CMOS SPAD ARRAYS

Traditional cameras include a sensor chip comprising an array of pixels, each of which measures the number of photons that strike the sensor at that particular position. Instead a SPAD measures not the number of photons but rather the time at which the first photon arrives. If the object is illuminated with a pulse of light then the arrival time of the first photon corresponds to the distance to that pixel – giving a 3D image.

Building upon the work in QuantIC phase one, contributions that we are making to the field include increasing the detection efficiency from <10% to ≈ 60%, improving the timing resolution (≈30ps -> depth resolution ≈5mm) and increasing the number of pixels in the image (256x256).

These cameras can measure the arrival time of every photon, allowing it to build up a 3D image of a scene or, measure the fluorescence of chemical markers in biological sciences. 

Video

SUPERCONDUCTING DETECTORS

In pushing the limits of single-photon detection, superconducting detectors offer an important alternative to semiconductor photon counters. 

A superconducting nanowire, cooled to a few degrees Kelvin, acts as a high-speed switch in response to infrared photons.  The absorbed photon perturbs current flow in the superconducting nanowire and can be detected as a fast voltage pulse. Photon detectors based on superconducting nanowires are sensitive to the widest possible range of wavelengths, can reach the ultimate sensitivity (≈90%) with negligible dark counts and reach the fastest response times (≈10ps).

QuantIC researchers are making these photon detectors more accessible by developing compact fridges so that they can be widely deployed in imaging trials with QuantIC partners. This work is being undertaken in conjunction with the Quantum Communications Hub. Detectors of this kind can be used in the monitoring of Photodynamic therapy and can be integrated into quantum microscopy systems.

Video

Daniele Faccio
Daniele Faccio

Imaging the human brain

Thu, 29 Jul 2021 07:56:00 BST

Read more

Healthcare connection image
Healthcare connection image

Revolutionising Biomedical Imaging

Thu, 22 Jul 2021 14:15:00 BST

Read more

FLIMera camera
FLIMera camera

Horiba launch FLIMera

Mon, 30 Nov 2020 17:40:00 GMT

Read more